منوی اصلیبستن
-
Dental
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Dental Finishing & Polishing
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
- Mag
-
Laboratory
-
-
Laboratory Equioment
-
-
-
-
Lab
-
-
-
Medical
-
-
-
-
تجهیزات تشخیص
-
تجهیزات عکس برداری
-
-
-
- Help
-
Corporate
-
- Login/ Register
-
منوی اصلیبستن
-
Dental
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Dental Finishing & Polishing
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
- Mag
-
Laboratory
-
-
Laboratory Equioment
-
-
-
-
Lab
-
-
-
Medical
-
-
-
-
تجهیزات تشخیص
-
تجهیزات عکس برداری
-
-
-
- Help
-
Corporate
-
- Login/ Register
- Home
- Dental Online Shop - Distributor & Supplier
- Dental Equipment & Accessories
- Dental Operatory Equipment
- Dental Laser
- Soft Tissue Laser
- Woodpecker - LX16 Diode Dental Laser
Woodpecker LX16 Dental Diode Laser | Dual Wavelength | Dandal
-
In line with the demand of Dandal site customers for credit purchases, Dandal in cooperation with Saman Bank has provided a new service for dental and medical offices and treatment centers, which customers can use a credit card from the site at any time without any cash support.
- More Info
پیش از خرید تجهیزات چه مواردی را بررسی کنیم؟
تناسب با نوع استفاده
نوع استفاده، حجم کار و انتظار خود از کالا را با مشخصات آن مقایسه کنید.
سازگاری با محیط کار
ابعاد، وزن، برق، اتصالات، فضای موردنیاز یا لوازم جانبی احتمالی را پیش از خرید بررسی کنید.
خدمات، قطعات و مصرفیهای وابسته
گارانتی، سرویس، قطعات، مصرفیها و لوازم جانبی مرتبط با کالا را در تصمیم خرید لحاظ کنید.
هزینه واقعی خرید
علاوه بر قیمت کالا، هزینههای احتمالی نصب، آموزش، سرویس، حمل و شرایط پرداخت را بررسی کنید.
Woodpecker LX16 Dental Diode Laser System
The Woodpecker LX16 Diode Laser System is a professional dual-wavelength dental laser designed for oral soft-tissue surgery, periodontal and endodontic procedures, pain management, photobiomodulation and other adjunctive dental applications.
Unlike the LX16 Plus, which incorporates three wavelengths, the standard LX16 operates with a primary 976 nm diode laser and a 650 nm low-level laser source. The 976 nm wavelength is intended for soft-tissue vaporization, carbonization and coagulation, while the 650 nm wavelength supports low-level laser therapy and aiming-beam functions.
The system combines a capacitive touchscreen, more than 20 preset clinical procedures, user-defined parameter control and a high-capacity rechargeable battery. Its autoclavable handpiece sleeve and fiber tip support effective infection-control protocols, while the automatic shutdown mechanism turns the unit off after five minutes of inactivity.
Key Features
- Dual-Wavelength Laser Technology
The LX16 incorporates two laser wavelengths:
- 976 ± 20 nm: soft-tissue surgery, vaporization, coagulation, periodontal and endodontic adjunctive procedures
- 650 ± 20 nm: low-level laser therapy, biostimulation, pain management and aiming-beam applications
The manufacturer specifies a maximum output of 16 W at 976 nm and 200 mW at 650 nm. The 976 nm source is classified as a Class IV laser, while the 650 nm source is classified as Class II according to IEC 60825-1.
More Than 20 Preset Treatment Procedures
The system includes over 20 preset clinical programs with predefined parameters. These protocols simplify setup and facilitate efficient use across different clinical indications.
Users can also adjust and save customized settings, including:
- Peak power
- Frequency
- Duty cycle
- Treatment time
- Wavelength
- Aiming-beam intensity
The system automatically calculates effective power and delivered energy based on the selected parameters.
Capacitive Touchscreen Interface
The touchscreen interface provides direct access to preset protocols, custom programs, operating instructions and treatment parameters. Effective power, energy and treatment time are displayed during parameter selection.
Rechargeable Battery Operation
The LX16 is powered by two rechargeable 11.1 V / 2600 mAh lithium batteries, providing a combined capacity of 57.7 Wh. The specified charging time is approximately four hours, or approximately five hours for the initial charge.
Battery-powered operation improves mobility and allows the unit to be transferred conveniently between treatment rooms.
Autoclavable Components
The handpiece sleeve and fiber tip can be autoclaved, helping the dental team maintain appropriate infection-control standards between patients.
Integrated Safety Features
The LX16 incorporates several operational safety mechanisms:
- Protective-eyewear warning
- Two-second countdown before Ready mode
- Emergency Laser Stop control
- Automatic shutdown after five minutes of inactivity
- Adjustable aiming beam
- Optional remote door interlock
- Standby and Ready operating states
- Internal control and protection system
All personnel present in the treatment room, including the clinician, assistant and patient, must wear manufacturer-approved laser safety eyewear during operation.
Clinical Applications
Soft-Tissue Surgery
Potential clinical applications include:
Gingivectomy
Gingivoplasty
Clinical crown lengthening
Frenectomy and frenotomy
Vestibuloplasty
Operculectomy
Gingival troughing
Excision of hyperplastic tissue
Fibroma removal
Incisional or excisional biopsy
Soft-tissue contouring
Local hemostasis
Exposure of unerupted teeth or implants
Periodontal Procedures
Periodontal pocket decontamination
Removal of inflamed or granulation tissue
Adjunctive treatment after scaling and root planing
Gingival tissue contouring
Local bacterial reduction
Adjunctive peri-implant soft-tissue management
- Endodontic Procedures
- Adjunctive root-canal disinfection
- Reduction of intracanal microbial load
- Supportive management of endodontic infection
- Photobiomodulation for postoperative discomfort
The laser should be considered an adjunct rather than a replacement for conventional mechanical preparation, irrigation and standard endodontic protocols.
- Restorative and Esthetic Dentistry
- Gingival troughing before impression-taking or digital scanning
- Soft-tissue management around restorative margins
- Exposure of subgingival preparation margins
- Gingival recontouring
- Hemostasis during restorative procedures
- Soft-tissue preparation before veneers and crowns
- Laser-assisted whitening with the appropriate accessory and protocol
- Photobiomodulation and Pain Management
The 650 nm wavelength may be used within appropriate low-level laser therapy protocols for:
- Local pain reduction
- Inflammation management
- Stimulation of tissue repair
- Adjunctive treatment of oral ulcers
- Postoperative discomfort
- Soft-tissue healing support
Important Clinical Notes
- The unit should only be operated by clinicians or technicians trained in dental laser safety.
- All individuals in the treatment room must wear wavelength-appropriate protective eyewear.
- The fiber tip must be activated before soft-tissue surgery according to the manufacturer’s instructions.
- The manufacturer describes activation using the 976 nm wavelength at 3 W continuous output with controlled contact against articulating paper.
- The fiber-optic cable must not be sharply bent, pulled or compressed.
- The device is rated IPX0 and must not be exposed to water.
- It must not be used in the presence of flammable anesthetic mixtures containing air, oxygen or nitrous oxide.
Contraindications and Precautions
According to the manufacturer’s instructions, the device must not be used in patients with hemophilia or cardiac pacemakers. Operators with pacemakers should not use the system. Special caution is advised for patients with cardiac disease, pregnant patients and young children.
Product Details
Data sheet
- Company/ Brand
- Woodpecker
- Country
- China
- Wave length
- 650±20 nm, 976±20 nm
- Laser Type
- Diode
بیشتر
Data sheet
- Company/ Brand
- Woodpecker
- Country
- China
- Wave length
- 650±20 nm, 976±20 nm
- Laser Type
- Diode