منوی اصلیبستن
-
Dental
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Dental Finishing & Polishing
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
- Mag
-
Laboratory
-
-
Laboratory Equioment
-
-
-
-
Lab
-
-
-
Medical
-
-
-
-
تجهیزات تشخیص
-
تجهیزات عکس برداری
-
-
-
- Help
-
Corporate
-
- Login/ Register
-
منوی اصلیبستن
-
Dental
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Dental Finishing & Polishing
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
- Mag
-
Laboratory
-
-
Laboratory Equioment
-
-
-
-
Lab
-
-
-
Medical
-
-
-
-
تجهیزات تشخیص
-
تجهیزات عکس برداری
-
-
-
- Help
-
Corporate
-
- Login/ Register
- Home
- Dental Online Shop - Distributor & Supplier
- Dental Equipment & Accessories
- Dental Sterilization Equipment
- Autoclave
- Dental X - Aquarius B 18Lit Autoclave
Dental X - Aquarius B Class 18Lit Autoclave - Dandal
-
In line with the demand of Dandal site customers for credit purchases, Dandal in cooperation with Saman Bank has provided a new service for dental and medical offices and treatment centers, which customers can use a credit card from the site at any time without any cash support.
- More Info
پیش از خرید تجهیزات چه مواردی را بررسی کنیم؟
تناسب با نوع استفاده
نوع استفاده، حجم کار و انتظار خود از کالا را با مشخصات آن مقایسه کنید.
سازگاری با محیط کار
ابعاد، وزن، برق، اتصالات، فضای موردنیاز یا لوازم جانبی احتمالی را پیش از خرید بررسی کنید.
خدمات، قطعات و مصرفیهای وابسته
گارانتی، سرویس، قطعات، مصرفیها و لوازم جانبی مرتبط با کالا را در تصمیم خرید لحاظ کنید.
هزینه واقعی خرید
علاوه بر قیمت کالا، هزینههای احتمالی نصب، آموزش، سرویس، حمل و شرایط پرداخت را بررسی کنید.
The AQUARIUS sterilization systems are the state of the art in the sterilization field.
Made out of advanced materials and components, the AQUARIUS sterilization systems combine, in a compact and elegant design, the performances of the most advanced hospital sterilization units.
The AQUARIUS 300 B systems are equipped with a powerful vacuum pump which enables the total air expulsion.
Thanks to the pump's action, it is possible to sterilize in a reliably way any kind of material, including the internal surfaces of handpieces. Moreover, the pump generates a forced ventilation and a perfect drying up.
Complying with what requested by the norms, AQUARIUS 300 B systems can carry out the Bowie & Dick test and the Helix test
In order to complete the offer, AQUARIUS 200 S is available with an advanced electronic air expulsion system that enable to fulfill the Class S requirements granting a simpler use and maintenance.
|
Feature |
Benefit |
|
Fractionated Vacuum: (3-4 phases)
|
Alleviates any risks of air pockets around instruments which may prevent sterilization. |
|
Ventilated Drying |
Ensures instruments are completely dry at the end of the cycle, preventing re-contamination and corrosion. |
|
Bacteriological Filter |
During the drying phase, the filter ensures bacteriologically pure air (filtration factor 99.97%). |
|
Differentiated Heating System |
The system consists of 5 heating elements distributed evenly in the chamber. The 300B has 3 temperature probes and an intelligent control program. Key advantages include, higher precision of temperature control, improved efficiency leading to better drying and reduced energy consumption. |
|
Self-Diagnostic & Troubleshooting |
A self-diagnostic cycle is completed every time the Series 300B is switched on to verify the correct operation of the unit. This cycle can be completed at any time. |
|
Double Water Tank |
1 tank for the supply of clean water and a separate tank for waste. The continuous use of clean water reduces maintenance and the need for technical service. |
|
Triple Safety Door |
The door is equipped with a triple safety locking system which prevents unintentional opening during operation. |
|
Computer Interface |
Information can be recorded and monitored easily via a computer. |
|
Integrated Printer (optional) |
A print out from each cycle can be easily checked and stored. |
|
Class B EN13060 : 2004 |
Capable of sterilizing a wide range of different instruments and equipment, including narrow lumens in hand pieces. In addition to a type B cycle, the Series 300B also provides a class S program ensuring maximum versatility of the machine. |
|
Water Quality Control System |
The water control system reduces the problems caused by poor water quality use and increase the reliability of the autoclave. |
|
Bowie & Dick Test
|
Provides assurance of the machines ability to sterilize porous loads.
|
|
Helix Test |
Provides assurance of the machines ability to sterilize objects with narrow lumens. |
|
Vacuum Test |
To check the integrity of the chamber and the vacuum system. |
Product Details
Data sheet
- Company/ Brand
- Dental X
- Country
- Italy
- Model
- Bench-top
- Weight
- 55Kg
بیشتر
Data sheet
- Company/ Brand
- Dental X
- Country
- Italy
- Model
- Bench-top
- Weight
- 55Kg