PURPOSE:

To compare the clinical effectiveness of two implant systems: Way Milano and Kentron (Geass, Pozzuolo del Friuli, UD, Italy).

MATERIALS AND METHODS:

A total of 64 patients requiring at least two single crowns or partial fixed dental prostheses supported by a maximum of three implants had their sites randomised according to a split-mouth design to receive both implant systems at six centres. Patients were followed up for 4 months after initial loading. Outcome measures were prosthesis/implant failures, any complication and clinician preference.

RESULTS:

In total, 71 Way Milano and 73 Kentron implants were placed. One patient died 45 days after placement of 2 implants, but all remaining patients were followed up to 4 months post-loading. No Way Milano implant failed whereas 3 Kentron implants failed before loading. Two complications were reported, one at each implant type. There were no statistically significant differences for prosthesis/ implant success and complications between the implant systems. Three operators preferred Way Milano implants whereas the other 3 had no preference.

CONCLUSIONS:

Preliminary short-term data (4 months post-loading) showed no statistically significant differences between the two implant systems, however trends were suggestive of a better clinical performance for Way Milano implants.

Source:PMID: 23926588 PubMed - indexed for MEDLINE

 

 

 