Ufit Implant Systems Overview
|
|
Ufit - Vt1
Octa Connection
|
|
|
|
Diameter 4.1 - 4.4 - 4.8 - 5.3 - 5.8
Height 7 - 8.5 - 10 - 11.5 - 13 - 15
|
Ufit - St1
Octa Connection
|
|
|
|
Diameter 4.1 - 4.4 - 4.8
Height 7 - 8.5 - 10 - 11.5 - 13 - 15
|
Ufit - Gt2
Hex Connection
|
|
|
|
Diameter 3.5 - 4 - 4.5 - 5 - 5.5 - 6 - 6.5 - 7
Height 8.5 - 10 - 11.5 - 13 - 15
|
|
Ufit - Nt2
Hex Connection
|
|
|
|
Diameter 3.5 - 4 - 4.5 - 5 - 5.5 - 6 - 6.5 - 7
Height 8.5 - 10 - 11.5 - 13 - 15
|
|
For more information Click on the above pictures.
|
Ufit has 4 models of fixture:
In a conventional abutment, the gap between fixture and abutment may increase gradually due to repeated chewing forces. This is due to the contact between the outer surface of the abutment and the inner taper of the fixture, which only occurs on a small surface area due to the roughness of both the two surfaces. On the other hand, SYLBUTMENT increases the contact surfaces by transformation to the grooves. It does not create a gap as the transformation between the two surfaces occurs within the elastic range.
Tissue Level Fixtures:
- Vt1
- St1
Vt1 Fixture
- 3.1 Octa indentation and 8 degree Morse Taper. (Upper part is compatible with ITI)
- Collar 1.8 Esthetic Type of Machined Surface
- As 0.8mm pitch of dual thread type, the surgery time is reduced. (1.6mm per 1 rotation)
- Surface areas are increased through blasting by highly biocompatible Calcium-Phosphate Media.
- When the fixture is inserted into the implant bed, the conical shape and lower deep thread of the fixture increase stability and make immediate loading possible.
- When placing the implants, the cutting edge of the Twist Type increases Self Tapping ability and minimizes Bone resistance.
- Apex has the dimension of D(fixture diameter)-0.7mm and the body shape has the overall tapered one.
St1 Fixture:
- 3.1 Octa indentation and 8 degree Morse Taper. (Upper part is compatible with ITI)
- Collar 1.8 Esthetic Type of Machined Surface
- As a form of streamline Round Thread, it is effective in stress distribution and prevents bone from the crack caused by the chewing forces.
- Surface areas are increased through blasting by highly biocompatible Calcium- Phosphate Media.
- Fin Type Design ---> When placing implants, initial guiding ability, stability and bone condensing effect is excellent.
- Due to the exterior Thread Taper design, initial penetration is excellent and surgical operation and drilling time is reduced.
- Reverse Engaging Flute ---> When placing implants, it gradually expands bones, inducing Self Engaging.
- When placing implants, it gradually expands bones, inducing Self Engaging.
Bone Level Fixtures:
- Gt2
- Nt2
- 2.5 Hex indentation and 11 degree Morse Taper.
- As 0.8mm pitch of dual thread type, the surgery time is reduced. (1.6mm per 1 rotation)
- Surface areas are increased through blasting by highly biocompatible Calcium-Phosphate Media.
- When the fixture is inserted into the implant bed, the conical shape and lower deep thread of the fixture increase stability and make immediate loading possible.
- When placing the implants, the cutting edge of the Twist Type increases Self Tapping ability and minimizes Bone resistance.
- Apex has the dimension of D(fixture diameter)-0.7mm and the body shape has the overall tapered one.
Also Gt2 Fixture has Micro threads with The deep of 0.2mm that increases the surface area and induces a smooth connection with the larger main thread. Additionally, the micro thread increases thread contact with bone thereby improving the initial fixation effect.
Author: Review department of Dandal.ir
First Release Date: 04/Jan/2016
Last Modified: 21/Aug/2016