Ufit Implant

 
Notify me when available

  • Out stock
  • Free

Pay in installments

Choose your plan:

Current plan: 3Month

Description: 30+3

Down payment: تومان0 (25.00%)

Number of payments: 3

Tax: تومان0

Amount of payment: تومان0

Overpayment: تومان0

Total: تومان1

Current plan: Cash

Description: نقدی

Down payment: تومان0 (0.00%)

Number of payments: 1

Tax: تومان0

Amount of payment: تومان1

Overpayment: تومان0

Total: تومان1

Ufit Implant Systems Overview

dandal

Ufit - Vt1

Octa Connection

ufit

Diameter 4.1 - 4.4 - 4.8 - 5.3 - 5.8

Height 7 - 8.5 - 10 - 11.5 - 13 - 15dandal

Ufit - St1

Octa Connection

ufit

Diameter 4.1 - 4.4 - 4.8

Height 7 - 8.5 - 10 - 11.5 - 13 - 15dandal

Ufit - Gt2

Hex Connection

ufit

Diameter 3.5 - 4 - 4.5 - 5 - 5.5 - 6 - 6.5 - 7

Height 8.5 - 10 - 11.5 - 13 - 15dandal

Ufit - Nt2

Hex Connection

ufit

Diameter 3.5 - 4 - 4.5 - 5 - 5.5 - 6 - 6.5 - 7

Height 8.5 - 10 - 11.5 - 13 - 15dandal


For more information Click on the above pictures.

           

        

Ufit has 4 models of fixture:

ufit

   

In a conventional abutment, the gap between fixture and abutment may increase gradually due to repeated chewing forces. This is due to the contact between the outer surface of the abutment and the inner taper of the fixture, which only occurs on a small surface area due to the roughness of both the two surfaces. On the other hand, SYLBUTMENT increases the contact surfaces by transformation to the grooves. It does not create a gap as the transformation between the two surfaces occurs within the elastic range.
    

ufit
    
Tissue Level Fixtures:

- Vt1
- St1

   

Vt1 Fixture

  • 3.1 Octa indentation and 8 degree Morse Taper. (Upper part is compatible with ITI)
  • Collar 1.8 Esthetic Type of Machined Surface
  • As 0.8mm pitch of dual thread type, the surgery time is reduced. (1.6mm per 1 rotation)
  • Surface areas are increased through blasting by highly biocompatible Calcium-Phosphate Media.
  • When the fixture is inserted into the implant bed, the conical shape and lower deep thread of the fixture increase stability and make immediate loading possible.
  • When placing the implants, the cutting edge of the Twist Type increases Self Tapping ability and minimizes Bone resistance.
  • Apex has the dimension of D(fixture diameter)-0.7mm and the body shape has the overall tapered one.
           

ufit

  

St1 Fixture:

  • 3.1 Octa indentation and 8 degree Morse Taper. (Upper part is compatible with ITI)
  • Collar 1.8 Esthetic Type of Machined Surface
  • As a form of streamline Round Thread, it is effective in stress distribution and prevents bone from the crack caused by the chewing forces.
  • Surface areas are increased through blasting by highly biocompatible Calcium- Phosphate Media.
  • Fin Type Design --->  When placing implants, initial guiding ability, stability and bone condensing effect is excellent.
  • Due to the exterior Thread Taper design, initial penetration is excellent and surgical operation and drilling time is reduced.
  • Reverse Engaging Flute ---> When placing implants, it gradually expands bones, inducing Self Engaging.
  • When placing implants, it gradually expands bones, inducing Self Engaging.
       

ufit

   

     

Bone Level Fixtures:

- Gt2
- Nt2

     

  • 2.5 Hex indentation and 11 degree Morse Taper.
  • As 0.8mm pitch of dual thread type, the surgery time is reduced. (1.6mm per 1 rotation)
  • Surface areas are increased through blasting by highly biocompatible Calcium-Phosphate Media.
  • When the fixture is inserted into the implant bed, the conical shape and lower deep thread of the fixture increase stability and make immediate loading possible.
  • When placing the implants, the cutting edge of the Twist Type increases Self Tapping ability and minimizes Bone resistance.
  • Apex has the dimension of D(fixture diameter)-0.7mm and the body shape has the overall tapered one.
       

ufit   

Also Gt2 Fixture has Micro threads with The deep of 0.2mm that increases the surface area and induces a smooth connection with the larger main thread. Additionally, the micro thread increases thread contact with bone thereby improving the initial fixation effect.

   

  

Author: Review department of Dandal.ir

First Release Date: 04/Jan/2016

Last Modified: 21/Aug/2016

          



Reference :

Data sheet

  • Ufit
  • South Korea
  • 2001
  • Unknown
  • 5
  • RBM
  • Yes
  • Yes
  • 7mm to 15mm
  • Hex | Octa
  • Yes
  • Fixture + Cover Screw
  • Yes
  • No
  • No
  • 5-8Ncm
  • 25-35Ncm
  • Unknown
  • Tapered | Cylindrical
  • No
  • 3.5mm to 7mm
  • ISO | CE | KFDA

Specific References

New product



Products accessories

Leave a comment about this product

Write your review

Ufit Implant

Write your review