LVD Biotech - Angiolite Sirolimus Eluting Cronary Stent

  Out-of-Stock 

Features:

Drug Eluting Stent

Spain Made

Cobalt Chromium Alloy

Sirolimus Drug

biostable fluoro acrylate polymer 

 
Notify me when available

  • Out stock
  • Free

Pay in installments

Choose your plan:

Current plan: 3Month

Description: 30+3

Down payment: تومان0 (25.00%)

Number of payments: 3

Tax: تومان0

Amount of payment: تومان0

Overpayment: تومان0

Total: تومان0

Current plan: 6 Month-2

Down payment: تومان0 (50.00%)

Number of payments: 6

Tax: تومان0

Amount of payment: تومان0

Overpayment: تومان0

Total: تومان0

Angiolite Sirolimus Eluting Cronary Stent

The sirolimus-eluting coronary stent angiolite, is made from a cobalt-chromium alloy called L605, coated with a mix of sirolimus and last generation of biostable polymers. The stent is pre-mounted on the delivery system that will allow implantation on the coronary lesion to treat, thanks to the inflation of a balloon at the distal end of the catheter.

The stent is manufactured from a metal tube that is laser cut and subsequently subjected to various treatments that will give the surface a smooth, glossy finish. The stent design is based on a concatenation of cells that are connected axially through links to obtain different longitudinal configurations. Moreover, the adjustment of the number of cells in the radial direction allows the stent to be expanded to different diameters. The result is an open-cell design.

 

LVD Biotech - Angiolite Sirolimus Eluting Cronary Stent

 

 

The stent delivery system is a rapid exchange balloon catheter also called RX, having a single lumen configuration on the proximal part and a coaxial double lumen configuration on the distal part. The catheter has an inflatable segment (balloon) in its distal end. The balloon is designed to achieve different diameters and lengths, engaging the stent in its different configurations and covering the range of lesions to be treated. 2 radiopaque markers are delimiting the length of the stent to facilitate observation under fluoroscopy. When the balloon reaches the lesion and is inflated, the stent expands against the artery. Subsequently, the balloon is deflated and removed and the stent remains permanently implanted.

The distal part of the catheter is coated with a durable hydrophilic coating to minimize friction and improve its trackability.
The inflatable segment is coated with a homogeneous mixture of the drug Sirolimus (Rapamycin) and a biostable fluoro acrylate polymer yielding a drug dose of 1.4 µg/mm2.

 

 LVD Biotech - Angiolite Sirolimus Eluting Cronary Stent

 

Specifications

Stent material: CoCr L605
Strut thickness: 75 µm – 85 µm
Recoil: < 5%
Shortening at expansion: < 3%
Drug: Sirolimus 1.4 µg/mm2
Polymer: Biostable fluorinated acrylate
Catheter materials: Nylon / Pebax. No latex components.
Semi-compliant balloon
Nominal pressure: 9 – 12 atm
Rated Burst Pressure (RBP): 16 atm
2 Pt/Ir radiopaque markers
Guiding catheter compatibility: 5F
Catheter’s working length: 142 cm
Recommended guidewire: 0.014”
Entry profile: 0.016”

 

LVD Biotech - Angiolite Sirolimus Eluting Cronary Stent



Reference :

Data sheet

  • Life Vascular Devices Biotech
  • Spain

Specific References

New product



Leave a comment about this product

Write your review

LVD Biotech - Angiolite Sirolimus Eluting Cronary Stent

Write your review