-
منوی اصلیبستن
-
Dental
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
- Mag
- Help
-
Corporate
-
- Login/ Register
-
منوی اصلیبستن
-
Dental
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
Gloves
-
-
-
- Mag
- Help
-
Corporate
-
- Login/ Register
- Home
- Medical & Surgical Equipment
- Medical & Surgical Supplies
- Cardiology
- CARDIOVASCULAR SURGERY
- Heart Valve
- Sorin - Crown PRT Aortic Heart Valve
Sorin - Crown PRT Aortic Heart Valve
-
In line with the demand of Dandal site customers for credit purchases, Dandal in cooperation with Saman Bank has provided a new service for dental and medical offices and treatment centers, which customers can use a credit card from the site at any time without any cash support.
- More Info
Sorin - Crown PRT Aortic Heart Valve
Out-of-StockFeatures:
Italy Made Aortic Heart Valve
latest advancement in stented aortic bioprosthesis technology
Pay in installments
Choose your plan:
Current plan: 3Month
Description: 30+3
Down payment: تومان0 (25.00%)
Number of payments: 3
Tax: تومان0
Amount of payment: تومان0
Overpayment: تومان0
Total: تومان0
Current plan: Cash
Description: نقدی
Down payment: تومان0 (0.00%)
Number of payments: 1
Tax: تومان0
Amount of payment: تومان0
Overpayment: تومان0
Total: تومان0
Crown PRT Aortic Heart Valve
CROWN PRT is the latest advancement in stented aortic bioprosthesis technology, featuring surgeon-friendly design, optimal hemodynamics and the patented Phospholipid Reduction Treatment (PRT) to bolster durability through mitigation of calcium uptake.
Crowning achievements
•Continuous Innovation
•Long Term Clinical Evidence
•Global Reach
Crowning design
•Smooth handling
•Straightforward implantability
•Ample versatility
Crowning performance
•Optimal hemodynamics
•Minimized patient prosthesis mismatch
•Proven durability
Features
Designed to Open Wide
Single bovine pericardium outer layer for maximized flow areas
CROWN PRT’s single bovine pericardium layer is mounted outside the stent. This optimizes hemodynamic performance by maximizing the flow area through a synchronous and unimpeded opening of the leaflets.
Designed to Last
One-seam knit polyester for smooth contact surface between pericardium and synthetic material.
Cushioned leaflet contact reduces pericardium wear, enhancing valve durability.
Cross-stitch pattern for even stress distribution on commissures.
By optimally distributing stress on the commissures, pressure forces on the valve posts are relieved during the cardiac cycle.
Treated to Last
Phospholipid reduction treatment (PRT) for mitigated calcium absorption
The presence of phospholipids in the pericardial tissue play a key role in the calcification process of bioprostheses as their phosphate heads are potential binding sites for circulating calcium ions.
Crown PRT features LivaNova’s patented Phospholipid Reduction Treatment (PRT) which has proved to decrease phospholipid content in pericardial tissue leading to a remarkable reduction of calcium uptakecompared to control tissue.
The PRT process removes phospholipids using Octanediol, a long chain alcohol that possesses a lipid-soluble tail to aid its solubility in phospholipids's heads and a water-soluble head to allow removal by rinsing pericardial layers before valve manufacturing.
Easy to Handle and Implant
Flexible stent for easy manipulation and structural resistance.
CROWN PRT’s two-minute rinse time makes intra-operative valve preparation fast and help save on aortic clamp time.
Flexible stent for easy manipulation and structural resistance.
CROWN PRT’s flexible stent provides resilience towards possible deformations during implant and robustness towards creep over time.
Visible markers for precise orientation and even suture placement.
CROWN PRT’s sewing cuff visible markers help precise valve placement and evenly distribute sutures.
Radiographic markers for sharp X-ray imaging.
CROWN PRT’s sewing cuff offers radio-opaque information on the precise position of commissures through a specially shaped insert, impregnated with tungsten powder.
Versatile
Slim, elastic sewing cuff for full conformability to the native annulus.
The malleable sewing cuff facilitates implantation by allowing full conformability to all types of annuli, even stiff/calcified and/or irregular roots.
The slim sewing ring also serves this goal and is slightly malleable so that implantation in stiff roots is facilitated.
The lowest profile tissue valve for clearance of coronary ostia and sino-tubular junction.
The malleable sewing cuff facilitates implantation by allowing full conformability to all types of annuli, even stiff/calcified and/or irregular roots.
Clearance of both coronary ostia and sino-tubular junction is assured, even in narrow aortic roots.
The low/flat profile also allows the surgeon greater visibility of the aortic anatomy during the procedure.
Coronary clearance is ensured by the flat profile, which also facilitates knot lowering.
Hemodynamics
In-vivo hemodynamics
The capability of LivaNova’s single bovine pericardial outer layer design to maximize flow areas through leaflets that open uniformly and wide has demonstrated excellent in-vivo hemodynamic performance since its introduction in the market in 1982. Literature overviews highlight low pressure gradients, large effective orifice areas and a remarkable regression on the left ventricular mass.
Durability
In-vitro durability
CROWN PRT's unique design shows outstanding resistance during accelerated wear testing at ISO 5840 conditions.
“No failures up to 1.5 billion cycles, equivalent to 37.5 years. Over 6 times the minimum requirement.”
In-vivo durability
LivaNova's single bovine pericardial outer layer design has over 21 years of published clinical data
proving already excellent durability without anti-calcification treatment.
“During the whole follow-up, which ranged up to 11 years, we recorded no reoperation because of failed prosthesis.”
In-Animal Calcium Absorption Mitigation Testing
By reducing the nucleation sites for calcium deposition - the phospholipids in the pericardial tissue - the Phospholipid Reduction Treatment (PRT) addresses directly the origin of tissue calcification which may lead to an enhanced valve durability. Tests in subcutaneous rat implants at 60 days demonstrate a significant reduction of calcium content in PRT-treated bovine pericardium patches compared to control.
Leave a comment about this product
Write your review
Sorin - Crown PRT Aortic Heart Valve